ED3L-04APA-FS02-UL

  • Servo drives with power rating 400W.
  • Single Phase 200-240VAC Input Voltage
  • User-configurable I/Os: 5 DI, 3 DO
  • Optional regenerative Brake resistor
  • Field Upgradable Firmware, Built-in USB Commissioning port
  • Keypad Interface
  • Built-in Common DC Bus function
  • Open-Loop Speed, Closed Loop Speed and Semi-Closed Loop Position (Message1, Message 111, Message 3/102/105+750 are available)
  • SINA_POS (FB284) provides Soft Limits, Homing, Torque Limit, Rel/ABS Position, Stop, Speed JOG, Continuous Position, …
  • 350% Overload capacity
  • Zero Tracking Control, One Parameter easy tunings
  • Motor Auto-detect through Encoder Cable
  • Motors with 17/23-bit ABS/Inc magnetic/optical encoders
  • Optional holding brake
SKU: ED3L-04APA-FS02-UL

This product is available & ready to ship.

15 People watching this product now!
Description

ED3L-04APA-FS02-UL is a 400W ProfiNet servo drive suitable for applications with PLC or ProfiNet -based motion controllers commanding the axis through ProfiNet network.

Specification

  DRIVE MODEL: ED3L-04APA-FS02-UL

Continuous output current [Arms] 2.9A
Maximum output current [Arms] 11.5A
Main power supply unit capacity [kVA] (single phase) 1.2KVA
Input Voltage [V] (Single phase)  200-240VAC -15% to +10% 50HZ/60HZ
Built-in Brake Resistor
Min. External Brake Resistor 45Ω/300W (Power varies depends on application requirement)
Circuit Breaker Current 4A Single- Phase (Slow Trip)
Recommended EMC Filter Schaffner FN3270H-10-44

Profinet Drive’s SPECIFICATION

Physical Layer 100BASE-TX (IEEE802.3)
Communications Standards IEC 61158 Type12, IEC 61800-7 CiA402 Drive Profile
FoE (File Over EtherCAT) Download a new firmware via FoE protocol
CiA402 Drive Profile Profile position mode
Profile velocity mode
Profile torque mode
Cyclic synchronous position & velocity and torque RT and IRT(Just in S7-1500)
Touch probe function High-Speed Position Capturing function through digital Inputs available on Drive

2x high-speed digital Inputs

Torque limit function
  Homing mode Support 32 kinds of Homing mode
Open Loop Speed Control AC1 : Message 1 Standard telegram1
Semi-Closed Loop Position control AC3 : Message 111 Standard telegram111
Close Loop Speed Control AC4 : Message 3 / 102 / 105 + 750)

 

Siemens telegram3 / 102 / 105 +

Message 750 (Auxiliary message)

Isochronous synchronizing cycle minimum is 500µs
Rated Power (W)

400

Input Voltage (V)

200-240

FLC Input Current (A)

1PH: 3.3A