ED3L-01APA-FS02-UL
- Servo drives with power rating 100W.
- Single Phase 200-240VAC Input Voltage
- User-configurable I/Os: 5 DI, 3 DO
- Optional regenerative Brake resistor
- Field Upgradable Firmware, Built-in USB Commissioning port
- Keypad Interface
- Built-in Common DC Bus function
- Open-Loop Speed, Closed Loop Speed and Semi-Closed Loop Position (Message1, Message 111, Message 3/102/105+750 are available)
- SINA_POS (FB284) provides Soft Limits, Homing, Torque Limit, Rel/ABS Position, Stop, Speed JOG, Continuous Position, …
- 350% Overload capacity
- Zero Tracking Control, One Parameter easy tunings
- Motor Auto-detect through Encoder Cable
- Motors with 17/23-bit ABS/Inc magnetic/optical encoders
- Optional holding brake
SKU:
ED3L-01APA-FS02-UL
This product is available & ready to ship.
15
People watching this product now!
Description
ED3L-01APA-FS02-UL is a 100W ProfiNet servo drive suitable for applications with PLC or ProfiNet -based motion controllers commanding the axis through ProfiNet network.
Specification
 DRIVE MODEL: ED3L-01APA-FS02-UL |
|
Continuous output current [Arms] | 1.1A |
Maximum output current [Arms] | 4.0A |
Main power supply unit capacity [kVA] (single phase) | 0.3KVA |
Input Voltage [V] (Single phase) | Â 200-240VAC -15% to +10% 50HZ/60HZ |
Built-in Brake Resistor | – |
Min. External Brake Resistor | 45Ω/300W (Power varies depends on application requirement) |
Circuit Breaker Current | 4A Single- Phase (Slow Trip) |
Recommended EMC Filter | Schaffner FN3270H-10-44 |
Profinet Drive’s SPECIFICATION
Physical Layer | 100BASE-TX (IEEE802.3) | |
Communications Standards | IEC 61158 Type12, IEC 61800-7 CiA402 Drive Profile | |
FoE (File Over EtherCAT) | Download a new firmware via FoE protocol | |
CiA402 Drive Profile | Profile position mode | |
Profile velocity mode | ||
Profile torque mode | ||
Cyclic synchronous position & velocity and torque | RT and IRT(Just in S7-1500) | |
Touch probe function | High-Speed Position Capturing function through digital Inputs available on Drive
2x high-speed digital Inputs |
|
Torque limit function | ||
Homing mode | Support 32 kinds of Homing mode | |
Open Loop Speed Control | AC1Â : Message 1 | Standard telegram1 |
Semi-Closed Loop Position control | AC3Â : Message 111 | Standard telegram111 |
Close Loop Speed Control | AC4Â : Message 3 / 102 / 105 + 750)
|
Siemens telegram3 / 102 / 105 +
Message 750 (Auxiliary message) |
Isochronous synchronizing cycle minimum is 500µs |
Â
Rated Power (W) |
100 |
---|---|
Input Voltage (V) |
200-240 |
FLC Input Current (A) |
1PH: 1.1A |
Command Source |
ProfiNET |
Downloads
Support
We're Here to Help
Need Help? Ask Us Now